Additional sturdy The up to date layout includes steel mounting legs through the total ATyS range, bettering the overall robustness of the switches. It also allows A better and difficulty-free of charge mounting on the switches on a back plate with preassembled screws.

Electricity backup The integrated Electricity backup offers transitional electricity to the product enabling position indication (change placement, timer position, fault notifications) and conversation to remain Lively with no source present for nearly thirty seconds.

Besides their built-in electrical power and Electricity measurement features (using a 2% precision stage), programmable inputs/outputs is usually utilised to control load shedding depending on a load amount or tariff.

ATyS p M are one-stage or three-phase modular automated transfer switches with favourable split indicator. They may be meant for use in minimal voltage electricity offer methods wherever a brief interruption in the load source is suitable through transfer.

Flexible programming ATyS p M time delays and inputs/outputs are fully configurable, for this reason enabling the simple checking of unique applications (load shedding, check…) along with the definition of an functioning cycle especially adapted in your application.

ข้อมูลไฟฟ้าน่ารู้, อุปกรณ์ไฟฟ้าอื่นๆ

รับประกอบตู้ไฟฟ้า – ตู้ควบคุมทุกชนิด

They've a completely programmable built-in an built-in ATS controller, permitting automatic transfer amongst two sources in key/genset or mains/mains purposes.

Configuration software program Computer software (Easyconfig) is accessible enabling the ATyS p parameters to get conveniently configured and the present configuration to get saved and despatched to other units.

ข้อมูลไฟฟ้าน่ารู้, อุปกรณ์ไฟฟ้าอื่นๆ, เครื่องมือช่าง

Integrated auxiliary contacts As Portion of the products monitoring purpose, the ATyS r enable the transmission of knowledge regarding their posture. This is possible due to the typical integration of the auxiliary Call for each posture.

Protection and reliability ATyS p have each electrical and mechanical interlocks for optimum safety. The 0 place provides electrical basic safety disconnection and lets TSE lockout as per IEC60947-three.

Fast commissioning On Original power up, the ATyS C65’s sensible wizard will guideline the operator in the commissioning process.

For more security, a tripping purpose is offered, allowing about to 0 position without the need of external ability provide in case of two resources blackoutand a long-lasting status monitoring together with communication function.

The ATyS t’s built-in controller has long been made to give just the features demanded for these software (Procedure with or without priority, desired supply collection) along with the monitoring from the voltage and frequency of this website the two source, for 3-section and single-phase networks.